41 research outputs found

    Infectious consequences of hematoma from cardiac implantable electronic device procedures and the role of the antibiotic envelope: A WRAP-IT trial analysis.

    Get PDF
    Hematoma is a complication of cardiac implantable electronic device (CIED) procedures and may lead to device infection. The TYRX antibacterial envelope reduced major CIED infection by 40% in the randomized WRAP-IT (World-wide Randomized Antibiotic Envelope Infection Prevention Trial) study, but its effectiveness in the presence of hematoma is not well understood.The purpose of this study was to evaluate the incidence and infectious consequences of hematoma and the association between envelope use, hematomas, and major CIED infection among WRAP-IT patients.All 6800 study patients were included in this analysis (control 3429; envelope 3371). Hematomas occurring within 30 days postprocedure (acute) were characterized and grouped by study treatment and evaluated for subsequent infection risk. Data were analyzed using Cox proportional hazard regression modeling.Acute hematoma incidence was 2.2% at 30 days, with no significant difference between treatment groups (envelope vs control hazard ratio [HR] 1.15; 95% confidence interval [CI] 0.84-1.58; P = .39). Through all follow-up, the risk of major infection was significantly higher among control patients with hematoma vs those without (13.1% vs 1.6%; HR 11.3; 95% CI 5.5-23.2; P.001). The risk of major infection was significantly lower in the envelope vs control patients with hematoma (2.5% vs 13.1%; HR 0.18; 95% CI 0.04-0.85; P = .03).The risk of hematoma was 2.2% among WRAP-IT patients. Among control patients, hematoma carried a11-fold risk of developing a major CIED infection. This risk was significantly mitigated with antibacterial envelope use, with an 82% reduction in major CIED infection among envelope patients who developed hematoma compared to control

    Risk Factors for CIED Infection After Secondary Procedures

    Get PDF
    OBJECTIVES This study aimed to identify risk factors for infection after secondary cardiac implantable electronic device (CIED) procedures. BACKGROUND Risk factors for CIED infection are not well defined and techniques to minimize infection lack supportive evidence. WRAP-IT (World-wide Randomized Antibiotic Envelope Infection Prevention trial), a large study that assessed the safety and efficacy of an antibacterial envelope for CIED infection reduction, offers insight into procedural details and infection prevention strategies. METHODS This analysis included 2,803 control patients from the WRAP-IT trial who received standard preoperative antibiotics but not the envelope (44 patients with major infections through all follow-up). A multivariate least absolute shrinkage and selection operator machine learning model, controlling for patient characteristics and procedural variables, was used for risk factor selection and identification. Risk factors consistently retaining predictive value in the model (appeared >10 times) across 100 iterations of imputed data were deemed significant. RESULTS Of the 81 variables screened, 17 were identified as risk factors with 6 being patient/device-related (nonmodifiable) and 11 begin procedure-related (potentially modifiable). Patient/device-related factors included higher number of previous CIED procedures, history of atrial arrhythmia, geography (outside North America and Europe), device type, and lower body mass index. Procedural factors associated with increased risk included longer procedure time, implant location (non-left pectoral subcutaneous), perioperative glycopeptide antibiotic versus nonglycopeptide, anticoagulant, and/or antiplatelet use, and capsulectomy. Factors associated with decreased risk of infection included chlorhexidine skin preparation and antibiotic pocket wash. CONCLUSIONS In WRAP-IT patients, we observed that several procedural risk factors correlated with infection risk. These results can help guide infection prevention strategies to minimize infections associated with secondary CIED procedures. (J Am Coll Cardiol EP 2022;8:101-111) (c) 2022 The Authors. Published by Elsevier on behalf of the American College of Cardiology Foundation. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/)

    the world wide randomized antibiotic envelope infection prevention wrap it trial long term follow up

    Get PDF
    Abstract Background The WRAP-IT trial reported a 40% reduction in major CIED infection within 12 months of the procedure with the antibacterial-eluting envelope (TYRX). Objective This report describes the longer-term (>12 months) envelope effects on infection reduction and complications. Methods All trial patients that underwent CIED replacement, upgrade, revision, or initial CRT-D implant received standard-of-care infection prophylaxis and were randomized 1:1 to receive the envelope or not. CIED infection incidence, and procedure and system-related complications were characterized through all follow-up (36 months) using Cox proportional hazard regression modeling. Results In total, 6800 patients received their intended randomized treatment (3371 envelope; 3429 control; mean follow-up 21.0±8.3 months). Major CIED-related infection occurred in 32 envelope patients and 51 control patients (KM estimate, 1.3% vs. 1.9%; HR: 0.64, 95% CI: 0.41-0.99; P=0.046). Any CIED-related infection occurred in 57 envelope patients and 84 control patients (KM estimate, 2.1% vs. 2.8%; HR: 0.69, 95% CI: 0.49-0.97; P=0.030). System- or procedure-related complications occurred in 235 envelope patients and 252 control patients (KM estimate, 8.0% vs. 8.2%; HR, 0.95, 95% CI: 0.79-1.13; P Conclusions The effects of the TYRX envelope in reducing the risk of CIED infection are sustained beyond the first year post-procedure, without increased risk of complication

    A Case of Pacemaker Endocarditis Caused by Aerococcus urinae

    No full text
    Background: Aerococcus urinae has lately been acknowledged as a cause of infective endocarditis (IE) especially in older males with underlying urinary tract disorders. In this population, cardiac implanted electronical devices (CIED) are not uncommon, but despite the capacity of A. urinae to form biofilm in vitro, no cases of aerococcal CIED infections have been reported to date.Case Presentation: An 84-year-old male with pacemaker was admitted with dysuria one month after a transurethral procedure for urinary bladder cancer. A. urinae was isolated from urine and blood. Transesophageal echocardiography (TEE) was without signs of vegetation on valves or pacing cables. The patient was treated with a twelve-day course of β-lactam antibiotics. Forty days after the initial admission, the patient was readmitted due to malaise, general pain of the joints, chills, and renewed blood cultures grew A. urinae. TEE demonstrated a 10 × 5 mm vegetation on either the tricuspid valve or one of the pacing cables. The pacemaker system was completely removed and demonstrated macroscopic signs of infection. A temporary system was implanted, and after 14 days of penicillin G treatment, a new system permanent system was implanted. Total treatment time was 40 days. Recovery was uneventful.Conclusion: This report demonstrates that A. urinae can cause CIED infection. In patients with A. urinae bacteremia and a CIED, this risk must be considered, especially if bacteremia reoccurs

    Current practice in transvenous lead extraction: a European Heart Rhythm Association EP Network Survey

    No full text
    AIM: Current practice with regard to transvenous lead extraction among European implanting centres was analysed by this survey. METHODS AND RESULTS: Among all contacted centres, 164, from 30 countries, declared that they perform transvenous lead extraction and answered 58 questions with a compliance rate of 99.9%. Data from the survey show that there seems to be an overall increasing experience of managing various techniques of lead extraction and a widespread involvement of cardiac centres in this treatment. Results and complication rates seem comparable with those of main international registries. CONCLUSION: This survey gives an interesting snapshot of lead extraction in Europe today and gives some clues for future research and prospective European registries
    corecore